Signal Conditioning - Powered
19 results found:
Matching categories: Signal Conditioning - Powered
4002ALM-6 Universal Trip Amplifier
£288.51
The 4002ALM-6 is a universal dual trip Amplifier accepting almost any process input including mA, volts, thermocouples and RTD's. The unit also has a 4-20mA or voltage output as standard,together with 2 x relay outputs. the 4002ALM-6 has every feature required built-in as standard.
£184.51
The Isocon-6 isolating signal converter can accept virtually any input including 4-20 mA, voltage, thermocouples, PT100 sensors and potentiometers and provide an isolated 4-20mA or Voltage output..
The Isocon-3 is also available if a AC power supply is required.
Slimcon-6 Signal Converter with Isolation
£136.44
The Slimcon-6 Signal Converter is the ultimate low cost, high accuracy compact signal converter.
The unit is a DC powered signal converter which can accept any 4-20mA or voltage input and provide an isolated 4-20mA or voltage output. Configurations is via DIP switches on the side of the unit.
The Slimcon-6 is housed in an ultra slim 6.4mm DIN rail enclosure saving panel space and money !
Dualcon-6 Dual Output isolating signal Converter
£275.31
The Dualcon-6 signal isolator accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provides two isolated 4-20mA or Voltage outputs.
the Dualcon-6 is powered from 16-36 Vdc Vac whilst the Dualcon-3 is also available if an AC power supply is required.
FREQCON Frequency to Analogue Converter
£212.43
The FREQCON-6 converter can convert virtually any frequency type input into an isolated 4-20mA or Voltage output. Any frequency between 0 and 250kHZ can be converted and almost any input voltage level can be read.
MATHSCON-6 Programmable Maths Unit
£247.46
The MATHSCON-6 performs a maths function on two inputs and provides an isolated 4-20mA or voltage output of the result. One of the inputs is universal the other is mA or voltage only.
Maths Functions include Average, Add, Subtract, Division, Multiply and Square Root. Custom functionality can also be supplied.
£184.51
The Isocon-3 isolating signal converter can accept virtually any input including 4-20 mA, voltage, thermocouples, PT100 sensors and potentiometers and provide an isolated 4-20mA or Voltage output..
The Isocon-6 is also available if a DC power supply is required.
Dualcon-3 Dual Output Isolating signal Converter
£275.31
The Dualcon-3 signal isolator accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provides two isolated 4-20mA or Voltage outputs.
the Dualcon-3 is powered from 90-264 Vac whilst the Dualcon-6 is also available if a DC power supply is required.
£184.51
The TC-TC is a Thermocouple Isolator which is used to isolate any thermocouple and provide an identical simulated mV thermocouple output.
Typically used to isolate thermocouples from input cards stopping any earth loop effects and eliminating any noise problems.
TC-TC-DUAL Thermocouple Isolator with 2 outputs
£275.31
The DCON-TCTC is a Thermocouple Isolator which is used to isolate any thermocouple and provide an identical simulated thermocouple output together with a second output which can also be a thermocouple output or a mA or Voltage output proportional to temperature.
The unit is typically used to isolate thermocouples from input cards stopping any earth loop effects and eliminating any noise problems.
Isocon-LIN Linearising Signal Converter
£184.51
The Isocon-LIN is a universal input DC powered signal converter which can linearise the output using up to 31 points of linearisation. The Isocon-LIN accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provides an isolated linearised mA or Voltage output.
The Isocon-6 has a 12-36Vdc power supply and the Isocon-3 is also available if a AC power supply is required.
Isocon-AVE Averaging Signal Converter
£184.51
The Isocon-AVE is a universal input signal converter which can average the output over any time period from 1s to 60 seconds. The Isocon-AVE accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provides an isolated averaged mA or Voltage output.
The Isocon-AVE-6 has a 12-36Vdc power supply and the Isocon-AVE-3 is also available if a AC power supply is required.
Isocon-DRIVE Isolating Signal Converterwith high current output
£184.51
The Isocon-DRIVE is a universal input DC powered signal converter which can output a high current output up to 125mA. The Isocon-DRIVE accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provides a high current output or up to 0-125mA which can be used to drive outputs such as ballast controllers or control valves.
The Isocon-6 has a 12-36Vdc power supply and the Isocon-3 is also available if a AC power supply is required.
STRAIN Universal Strain Gauge Transmitter
£184.51
The STRAIN universal strain gauge transmitter can connect with almost any strain gauge, loadcell or pressure transducer and provides an isolated 4-20mA or voltage output. Virtually any 4-wire strain gauge or load cell can be connected with the unit supplying a 10Vdc excitation voltage.
Two versions are available, the STRAIN-6 with a 12-36Vdc supply or the STRAIN-3 with a 90-264 Vac supply
STRAIN-DUAL Universal Strain Gauge Transmitter with two outputs
£275.31
The STRAIN-Dual universal strain gauge transmitter can connect with almost any strain gauge, loadcell or pressure transducer and provides two isolated 4-20mA or voltage outputs. Virtually any 4-wire strain gauge or load cell can be connected with the unit supplying a 10Vdc excitation voltage.
Two versions are available, the STRAIN-DUAL-6 with a 16-36Vdc supply or the STRAIN-DUAL-3 with a 90-264 Vac supply
Dualcon-AVE Dual Output converter with output averaging
£275.31
The Dualcon-AVE accepts virtually any input including 4-20mA loops, voltage inputs, thermocouples, PT100 sensors and potentiometers and provide two isolated 4-20mA or Voltage outputs which can be averaged over a time period from 1s to 60s.
The Dualcon-AVE-6 has a 16Vdc to 36Vdc supply and the Dualcon-AVE-3 is also available if a AC power supply is required.
FREQCON-IPWM Analogue to PWM Frequency Converter
£212.43
The FREQCON-IPWM converter accepts any type of process input and provides a PWM output.
This is typically used with units such as PLC's which don't have an analogue input but do have a PWM input.
Using the FREQCON-IPWM mA, thermocouple, RTD, or voltage signal can be converted to a PWM output which can then be fed into a PLC or similar device.
FREQCON-PWMI PWM Frequency to Analogue Converter
£212.43
The FREQCON-PWMI converter can convert virtually any PWM type input into an isolated 4-20mA or Voltage output. Any frequency between 0 and 250kHZ can be converted and almost any input voltage level can be read.
VOLTCON High Voltage Isolating Converter
£265.00
This range of isolated signal converters can accept a wide range of AC and DC voltages and provide an isolated
4-20mA output. Voltages up to 500V AC or DC can be converted.
The device uses a true RMS input stage which allows accurate measurement of non-perfect AC waveforms.